Thickness 50-60-80-100-120-150 [mm]
Width 1000 [mm]
Insulation: mineral wool
Concealed installation
SPECIFICATION OF RW PANELS | |||||||||
Nominal thickenss (mm) |
50 |
60 |
80 |
100 |
120 |
150 |
200 |
240 |
|
Weight (Kgr/m²) Steel thickness 0,50/0,50 |
14.5 |
15.7 |
18.1 |
20.5 |
22.9 |
26.5 |
32.5 |
37.3 |
|
Weight (Kgr/m²) Steel thickness 0,60/0,60 |
10.3 |
10.4 |
10.7 |
11.0 |
11.3 |
11.7 |
12.4 |
13.0 |
|
U value Thermal conductivity (W/m²K) |
0.64 |
0.54 |
0.41 |
0.33 |
0.27 |
0.22 |
0.20 |
0.17 |
|
Combustibility of core | Non combustible / Class A1 acc. to EN13501 | ||||||||
Effective width | 1000mm | ||||||||
Panel legth | 2000 – 15000mm | ||||||||
Maximum recommended legth (mm) (Steel thickness 0,50mm) |
6.000 |
7.000 |
8.000 |
9.000 |
9.500 |
10.000 |
10.5000 |
11.000 |
|
Maximum recommended legth (mm) (Steel thickness 0,60mm) |
7.000 |
8.000 |
9.000 |
9.500 |
10.000 |
10.500 |
11.000 |
12.000 |
|
Recommended self drill screws |
6.3 x 60 |
6.3×90 |
6.3×100 |
6.3×120 |
6.3×120 |
6.3×200 |
6.3×250 |
6.3×300 |
RW WALL PANELS
Distributed Overload (daN/m²) 1daN/m²=1,02 kp/m² |
||||||||||||||
40 |
60 |
80 |
100 |
120 |
150 |
200 |
40 |
60 |
80 |
100 |
120 |
150 |
200 |
|
Thickness (mm) | ||||||||||||||
50 |
4.47 |
3.68 |
2.78 |
2.26 |
1.9 |
1.54 |
1.15 |
4.66 |
3.89 |
3.26 |
2.61 |
2.2 |
1.77 |
1.23 |
60 |
4.92 |
4.09 |
3.37 |
2.7 |
2.31 |
1.7 |
1.23 |
5.12 |
4.24 |
4.59 |
3.02 |
2.62 |
2.18 |
1.32 |
80 |
5.74 |
4.77 |
4.41 |
3.58 |
3.02 |
2.43 |
1.42 |
6.05 |
4.95 |
4.29 |
3.83 |
3.47 |
2.82 |
1.59 |
100 |
6.03 |
5.05 |
4.69 |
4.46 |
3.68 |
2.99 |
2.23 |
6.78 |
5.54 |
4.79 |
4.29 |
3.91 |
3.49 |
2.44 |
120 |
7.1 |
5.75 |
5.02 |
4.78 |
4.32 |
3.45 |
2.51 |
7.45 |
6.05 |
5.24 |
4.7 |
4.29 |
3.84 |
2.82 |
150 |
7.81 |
6.33 |
5.64 |
5.04 |
4.56 |
3.69 |
2.69 |
8.27 |
6.75 |
5.85 |
5.23 |
4.77 |
4.25 |
3.01 |
Deflection limit: f< l/200 of the span |